Is it possible to run a contact program with XM generator and SC contact 100 kHz fixed at the same time?

It is not recommended. Current flow will take the shortest path to ground.

You could have the 320v of the SC go to the XM and cause issues.

This is also why using two or more more generators in contact mode is not recommended.

You can; however, use both outputs of one single generator to drive 2 sets of TENS for 4 contact pads.

This is because both Out 1 and Out 2 share a common power supply.

Wire one set of TENS to Out 1 directly, and the other to Out 2 directly.

Switch the preset from inverse+sync to Follow Out 1.

Note that with 4 TENS pads, you can not use the boost. Therefore; while coverage will be better, the output power will be one quarter the strength.

For more details, please check the link from:
https://www.facebook.com/groups/spooky2/permalink/728274980667741/

Was this article helpful?
0 out of 0 found this helpful

Comments

0 comments

Please sign in to leave a comment.

Articles in this section

See more
Our Blog
Get the latest news and updates first
Our helpline hours:
9 AM – 6PM UTC+8, Monday – Friday
Video Guides
Learn how to use Spooky2 with our short, step-by-step video guides